Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com
GU-139-Jpage 13 of 29
IA4100
Administrator Guide
11 Basic Programming
PROGRAMMING
COMMANDS DURING A CALL
AUXILIARY OUTPUTS (default settings)
IA4100 DIAGRAM
Battery 12v @ 2.0AhrBattery 12V @ 2.0Ahr
Aux Outputs
1
2 3
PAS Control
PAS Audio
Audio
Output
Phone
Line
Acc
Power
Grd
Battery
Aux
Inputs
+
–
–
+ –
1
3
2
4
N.O.
N.C.
1
2
to strobe unit
Auxiliary Output #1 closed until the end of the call
Auxiliary Output #3
closed for one second momentary
contact closure
20 increase microphone gain
21 decrease microphone gain
22 speaker volume up
23 speaker volume down
24 microphone mute
25 speaker mute
01 play message #1
02 play message #2
11 turn on auxiliary output 1
13 turn on auxiliary output 3
14 turn off auxiliary output 1
16 turn off auxiliary output 3
12583# programming mode
99Ý99#
defaults phone
57# trains the phone on the local loop
5000# give up waiting for dial tone
4108# revert to dial tone hangup
4308# repeating (reorder) tone hangup
Ý#
hang up and exit programming
3. PROGRAMMING FOR HOT LINE (RING-DOWN)
Call the extension or phone number of CB Unit, after the RFA tone:
If messages are required see section 3.
12583# programming mode
21# <your message> #
plays to end user at CB unit when
HELP activated
22# <your message> #
plays to end user at CB unit AND called
party when call is answered
Ý#
hang up and exit programming
4. RECORDING MESSAGES
Call the extension or phone number of CB Unit, after the RFA tone:
The following commands can be used by the called party
after the IA4100 places a call. These commands cannot
be used in Programming Mode.
12583# programming mode
99Ý99#
defaults the phone
57# trains the phone on the local loop
4108# revert to dial tone hangup
4308# repeating (reorder) tone hangup
01 <phone number> # 1st phone number, button #1 dials
02 <phone number> # 2nd phone number, button #1 dials
04 <phone number> # 1st phone number, button #2 dials
05 <phone number> # 2nd phone number, button #2 dials
Ý#
hang up and exit programming
1. NORMAL PROGRAMMING
Call the extension or phone number of CB unit, after the RFA tone:
Control cable and PAS audio cable,
supplied with PAS amp
12583# programming mode
99Ý99#
defaults phone
57# trains the phone on the local loop
4108# revert to dial tone hangup
4308# repeating (reorder) tone hangup
5145# unique GSM programming command
5245# unique GSM programming command
01 <phone number> # 1st phone number, button #1 dials
04 <phone number> # 1st phone number, button #2 dials
Ý#
hang up and exit programming
2. GSM CELLULAR PROGRAMMING
Call the extension or phone number of CB Unit, after the RFA tone:
Failure to program in any number will result in a failure to
operate.